TY - JOUR
T1 - Rapid, accurate computation of narrow-band sky radiance in the 940 nm gas absorption region using the correlated k-distribution method for sun-photometer observations
AU - Momoi, Masahiro
AU - Irie, Hitoshi
AU - Sekiguchi, Miho
AU - Nakajima, Teruyuki
AU - Takenaka, Hideaki
AU - Miura, Kazuhiko
AU - Aoki, Kazuma
N1 - Publisher Copyright:
© 2022, The Author(s).
PY - 2022/12
Y1 - 2022/12
N2 - We developed lookup tables for the correlated k-distribution (CKD) method in the 940 nm water vapor absorption region (WV-CKD), with the aim of rapid and accurate computation of narrow-band radiation around 940 nm (10,000–10,900 cm - 1) for ground-based angular-scanning radiometer data analysis. Tables were constructed at three spectral resolutions (2, 5, and 10 cm - 1) with quadrature values (point and weight) and numbers optimized using simulated sky radiances at ground level, which had accuracies of ≤ 0.5% for sub-bands of 10 cm - 1. Although high-resolution WV-CKD requires numerous quadrature points, the number of executions of the radiative transfer model is reduced to approximately 1/46 of the number used in the line-by-line approach by our WV-CKD with a resolution of 2 cm - 1. Furthermore, we confirmed through several simulations that WV-CKD could be used to compute radiances with various vertical profiles. The accuracy of convolved direct solar irradiance and diffuse radiance at a full width at half maximum (FWHM) of 10 nm, computed with the WV-CKD, is < 0.3%. In contrast, the accuracy of convolved normalized radiance, which is the ratio of diffuse radiance to direct solar irradiance, at an FWHM of 10 nm computed with the WV-CKD is < 0.11%. This accuracy is lower than the observational uncertainty of a ground-based angular-scanning radiometer (approximately 0.5%). Finally, we applied the SKYMAP and DSRAD algorithms (Momoi et al. in Atmos Meas Tech 13:2635–2658, 2020. https://doi.org/10.5194/amt-13-2635-2020) to SKYNET observations (Chiba, Japan) and compared the results with microwave radiometer values. The precipitable water vapor (PWV) derived with the WV-CKD showed better agreement (correlation coefficient γ = 0.995, slope = 1.002) with observations than PWV derived with the previous CKD table (correlation coefficient γ = 0.984, slope = 0.926) by Momoi et al. (Momoi et al., Atmos Meas Tech 13:2635–2658, 2020). Through application of the WV-CKD to actual data analysis, we found that an accurate CKD table is essential for estimating PWV from sky-radiometer observations. [Figure not available: see fulltext.]
AB - We developed lookup tables for the correlated k-distribution (CKD) method in the 940 nm water vapor absorption region (WV-CKD), with the aim of rapid and accurate computation of narrow-band radiation around 940 nm (10,000–10,900 cm - 1) for ground-based angular-scanning radiometer data analysis. Tables were constructed at three spectral resolutions (2, 5, and 10 cm - 1) with quadrature values (point and weight) and numbers optimized using simulated sky radiances at ground level, which had accuracies of ≤ 0.5% for sub-bands of 10 cm - 1. Although high-resolution WV-CKD requires numerous quadrature points, the number of executions of the radiative transfer model is reduced to approximately 1/46 of the number used in the line-by-line approach by our WV-CKD with a resolution of 2 cm - 1. Furthermore, we confirmed through several simulations that WV-CKD could be used to compute radiances with various vertical profiles. The accuracy of convolved direct solar irradiance and diffuse radiance at a full width at half maximum (FWHM) of 10 nm, computed with the WV-CKD, is < 0.3%. In contrast, the accuracy of convolved normalized radiance, which is the ratio of diffuse radiance to direct solar irradiance, at an FWHM of 10 nm computed with the WV-CKD is < 0.11%. This accuracy is lower than the observational uncertainty of a ground-based angular-scanning radiometer (approximately 0.5%). Finally, we applied the SKYMAP and DSRAD algorithms (Momoi et al. in Atmos Meas Tech 13:2635–2658, 2020. https://doi.org/10.5194/amt-13-2635-2020) to SKYNET observations (Chiba, Japan) and compared the results with microwave radiometer values. The precipitable water vapor (PWV) derived with the WV-CKD showed better agreement (correlation coefficient γ = 0.995, slope = 1.002) with observations than PWV derived with the previous CKD table (correlation coefficient γ = 0.984, slope = 0.926) by Momoi et al. (Momoi et al., Atmos Meas Tech 13:2635–2658, 2020). Through application of the WV-CKD to actual data analysis, we found that an accurate CKD table is essential for estimating PWV from sky-radiometer observations. [Figure not available: see fulltext.]
KW - Atmospheric gas absorption
KW - Correlated k-distribution
KW - Radiative transfer
UR - http://www.scopus.com/inward/record.url?scp=85124014333&partnerID=8YFLogxK
U2 - 10.1186/s40645-022-00467-6
DO - 10.1186/s40645-022-00467-6
M3 - 学術論文
AN - SCOPUS:85124014333
SN - 2197-4284
VL - 9
JO - Progress in Earth and Planetary Science
JF - Progress in Earth and Planetary Science
IS - 1
M1 - 10
ER -