Pneumothorax during laparoscopy

Y. Miyamoto*, A. Higuchi, K. Kamitani, K. Shakunaga

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

2 Scopus citations

Abstract

A 28-year-old female was scheduled for laparoscopy under general anesthesia. Her history and physical examination were unremarkable. Trachea was intubated uneventfully following intravenous administration of thiopental 200 mg and vecuronium 8 mg. Anesthesia was maintained with 40% O2, 60% N2O and sevoflurane. Shortly after pneumoperitoneum was introduced, airway resistance increased and breathing sounds were hardly audible over the right side of the chest. A chest radiograph showed the right pneumothorax. Immediately after evacuating the peritoneal gas, the chest radiograph and a blood gas analysis showed that the pneumothorax had improved. Pneumothorax can occur subsequently to pneumoperitoneum due to passage of gas through weak points or defects in the diaphragm. Breathing sound should be monitored carefully during the laparoscopic surgery. Anesthetic gas analyzer and capnometer are considered to be useful to confirm the cause of the pneumothorax.

Original languageEnglish
Pages (from-to)1311-1313
Number of pages3
JournalJapanese Journal of Anesthesiology
Volume41
Issue number8
StatePublished - 1992

ASJC Scopus subject areas

  • Anesthesiology and Pain Medicine

Fingerprint

Dive into the research topics of 'Pneumothorax during laparoscopy'. Together they form a unique fingerprint.

Cite this