TY - JOUR
T1 - EUS-guided fine-needle biopsy sampling of solid pancreatic tumors with 3 versus 12 to-and-fro movements
T2 - a multicenter prospective randomized controlled study
AU - Takahashi, Kosuke
AU - Yasuda, Ichiro
AU - Hayashi, Nobuhiko
AU - Iwashita, Takuji
AU - Okuno, Mitsuru
AU - Mukai, Tsuyoshi
AU - Mabuchi, Masatoshi
AU - Adachi, Seiji
AU - Doi, Shinpei
AU - Imura, Johji
AU - Ozawa, Eisuke
AU - Miyaaki, Hisamitsu
AU - Nakao, Kazuhiko
N1 - Publisher Copyright:
© 2023 American Society for Gastrointestinal Endoscopy
PY - 2023/6
Y1 - 2023/6
N2 - Background and Aims: A novel EUS-guided fine-needle biopsy sampling (EUS-FNB) needle enabled physicians to obtain sufficient pathologic samples with fewer to-and-fro movements (TAFs) within the lesion. We compared the diagnostic yields of EUS-FNB with 3 and 12 TAFs at each puncture pass. Methods: The primary endpoint of this multicenter, noninferiority, crossover, randomized controlled trial involving 6 centers was diagnostic sensitivity. Secondary endpoints were diagnostic accuracy and quantity and quality evaluation of EUS-FNB specimens. Length of the macroscopically visible core (MVC) and microscopic histologic quantity were used for quantitative evaluation. Macroscopic visual and microscopic histologic evaluations were performed for qualitative evaluation. Results: Among 110 patients (220 punctures, 110 for 3 TAFs and 12 TAFs each), 105 (210 punctures) had malignant histology. Diagnostic sensitivity for malignancy of 3 TAFs (88.6%) was not inferior to that of 12 TAFs (89.5%; difference, –.9%; 95% confidence interval, –9.81 to 7.86). Diagnostic accuracy for malignancy was 92.7% for 3 TAFs and 94.6% for 12 TAFs. Overall median MVC length was 13.5 mm in both groups. The 3-TAF group had a significantly higher rate of score ≥3 on macroscopic visual quality evaluation than the 12-TAF group (71.8% vs 52.7%, P =.009). No significant intergroup differences existed in microscopic histologic quantity and quality evaluations (quantity evaluation, 88.2% for 3 TAFs vs 83.6% for 12 TAFs; quality evaluation, 90.0% for 3 TAFs vs 89.1% for 12 TAFs). Conclusions: Diagnostic sensitivity and accuracy of EUS-FNB with 3 TAFs were not inferior to those with 12 TAFs for solid pancreatic lesions. The 3-TAF group showed significantly less blood contamination in sampled tissues than the 12-TAF group. (Clinical trial registration number: UMIN000037309.)
AB - Background and Aims: A novel EUS-guided fine-needle biopsy sampling (EUS-FNB) needle enabled physicians to obtain sufficient pathologic samples with fewer to-and-fro movements (TAFs) within the lesion. We compared the diagnostic yields of EUS-FNB with 3 and 12 TAFs at each puncture pass. Methods: The primary endpoint of this multicenter, noninferiority, crossover, randomized controlled trial involving 6 centers was diagnostic sensitivity. Secondary endpoints were diagnostic accuracy and quantity and quality evaluation of EUS-FNB specimens. Length of the macroscopically visible core (MVC) and microscopic histologic quantity were used for quantitative evaluation. Macroscopic visual and microscopic histologic evaluations were performed for qualitative evaluation. Results: Among 110 patients (220 punctures, 110 for 3 TAFs and 12 TAFs each), 105 (210 punctures) had malignant histology. Diagnostic sensitivity for malignancy of 3 TAFs (88.6%) was not inferior to that of 12 TAFs (89.5%; difference, –.9%; 95% confidence interval, –9.81 to 7.86). Diagnostic accuracy for malignancy was 92.7% for 3 TAFs and 94.6% for 12 TAFs. Overall median MVC length was 13.5 mm in both groups. The 3-TAF group had a significantly higher rate of score ≥3 on macroscopic visual quality evaluation than the 12-TAF group (71.8% vs 52.7%, P =.009). No significant intergroup differences existed in microscopic histologic quantity and quality evaluations (quantity evaluation, 88.2% for 3 TAFs vs 83.6% for 12 TAFs; quality evaluation, 90.0% for 3 TAFs vs 89.1% for 12 TAFs). Conclusions: Diagnostic sensitivity and accuracy of EUS-FNB with 3 TAFs were not inferior to those with 12 TAFs for solid pancreatic lesions. The 3-TAF group showed significantly less blood contamination in sampled tissues than the 12-TAF group. (Clinical trial registration number: UMIN000037309.)
UR - http://www.scopus.com/inward/record.url?scp=85152560409&partnerID=8YFLogxK
U2 - 10.1016/j.gie.2023.01.037
DO - 10.1016/j.gie.2023.01.037
M3 - 学術論文
C2 - 36702383
AN - SCOPUS:85152560409
SN - 0016-5107
VL - 97
SP - 1092
EP - 1099
JO - Gastrointestinal Endoscopy
JF - Gastrointestinal Endoscopy
IS - 6
ER -