TY - JOUR
T1 - Diagnostic fine-needle biopsy of small solid pancreatic lesions using a franseen needle during endoscopic ultrasound examination
AU - Takahashi, Kosuke
AU - Yasuda, Ichiro
AU - Hanaoka, Tatsuyuki
AU - Hayashi, Yuka
AU - Araki, Yasuhiro
AU - Motoo, Iori
AU - Kajiura, Shinya
AU - Ando, Takayuki
AU - Fujinami, Haruka
AU - Tajiri, Kazuto
AU - Minemura, Masami
AU - Takahara, Terumi
N1 - Publisher Copyright:
© 2020 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2021/1
Y1 - 2021/1
N2 - Background and aim: During endoscopic ultrasound-guided fine needle aspiration biopsy (EUS-FNB), Franseen needles can help collect sufficient tissue to permit histopathological assessment. However, its efficacy might be limited by the size of the targeted lesion. This study aimed to evaluate the feasibility of histopathological assessment of small solid pancreatic lesions using a 22-gauge Franseen needle during EUS-FNB. Methods: This retrospective study evaluated data from all patients who underwent EUS-FNB using a Franseen needle for solid pancreatic lesions at the University of Toyama Hospital between June 2018 and April 2020. Results: The study included 159 patients who had 152 malignant lesions and 7 benign lesions. The malignant lesions included pancreatic cancers (n = 134), neuroendocrine neoplasms (n = 15), metastatic tumors (n = 2), and a solid pseudopapillary neoplasm (n = 1). The diagnostic accuracy of EUS-FNB (combining histology and cytology) was 98.7%. However, the histopathological diagnosis was only confirmed for 64.3% of small lesions (<10 mm), relative to 97.2% for larger lesions. Multivariate analysis also revealed that lesion size of <10 mm predicted a less accurate histopathological diagnosis (odds ratio: 6.97, 95% confidence interval: 1.02–47.67; p = 0.041). Further analyses revealed a failed histological diagnosis in 4 patients with lesions of <5 mm in size and accurate diagnoses in 9 out of 10 patients with lesions of 5–10 mm in size. Conclusions: The diagnostic accuracy for small lesions (<10 mm), especially for lesions of <5 mm, based on histological examination alone, was significantly lower than that for others (>10 mm). Furthermore, multivariate analysis revealed that only lesion size was an independent predictor of histopathological diagnosis accuracy.
AB - Background and aim: During endoscopic ultrasound-guided fine needle aspiration biopsy (EUS-FNB), Franseen needles can help collect sufficient tissue to permit histopathological assessment. However, its efficacy might be limited by the size of the targeted lesion. This study aimed to evaluate the feasibility of histopathological assessment of small solid pancreatic lesions using a 22-gauge Franseen needle during EUS-FNB. Methods: This retrospective study evaluated data from all patients who underwent EUS-FNB using a Franseen needle for solid pancreatic lesions at the University of Toyama Hospital between June 2018 and April 2020. Results: The study included 159 patients who had 152 malignant lesions and 7 benign lesions. The malignant lesions included pancreatic cancers (n = 134), neuroendocrine neoplasms (n = 15), metastatic tumors (n = 2), and a solid pseudopapillary neoplasm (n = 1). The diagnostic accuracy of EUS-FNB (combining histology and cytology) was 98.7%. However, the histopathological diagnosis was only confirmed for 64.3% of small lesions (<10 mm), relative to 97.2% for larger lesions. Multivariate analysis also revealed that lesion size of <10 mm predicted a less accurate histopathological diagnosis (odds ratio: 6.97, 95% confidence interval: 1.02–47.67; p = 0.041). Further analyses revealed a failed histological diagnosis in 4 patients with lesions of <5 mm in size and accurate diagnoses in 9 out of 10 patients with lesions of 5–10 mm in size. Conclusions: The diagnostic accuracy for small lesions (<10 mm), especially for lesions of <5 mm, based on histological examination alone, was significantly lower than that for others (>10 mm). Furthermore, multivariate analysis revealed that only lesion size was an independent predictor of histopathological diagnosis accuracy.
KW - EUS-FNB
KW - Franseen needle
KW - Histopathological assessment
KW - Small pancreatic lesions
UR - http://www.scopus.com/inward/record.url?scp=85107658235&partnerID=8YFLogxK
U2 - 10.3390/diagnostics11010027
DO - 10.3390/diagnostics11010027
M3 - 学術論文
C2 - 33375661
AN - SCOPUS:85107658235
SN - 2075-4418
VL - 11
JO - Diagnostics
JF - Diagnostics
IS - 1
M1 - 27
ER -