Diagnostic fine-needle biopsy of small solid pancreatic lesions using a franseen needle during endoscopic ultrasound examination

Kosuke Takahashi, Ichiro Yasuda*, Tatsuyuki Hanaoka, Yuka Hayashi, Yasuhiro Araki, Iori Motoo, Shinya Kajiura, Takayuki Ando, Haruka Fujinami, Kazuto Tajiri, Masami Minemura, Terumi Takahara

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

19 Scopus citations

Abstract

Background and aim: During endoscopic ultrasound-guided fine needle aspiration biopsy (EUS-FNB), Franseen needles can help collect sufficient tissue to permit histopathological assessment. However, its efficacy might be limited by the size of the targeted lesion. This study aimed to evaluate the feasibility of histopathological assessment of small solid pancreatic lesions using a 22-gauge Franseen needle during EUS-FNB. Methods: This retrospective study evaluated data from all patients who underwent EUS-FNB using a Franseen needle for solid pancreatic lesions at the University of Toyama Hospital between June 2018 and April 2020. Results: The study included 159 patients who had 152 malignant lesions and 7 benign lesions. The malignant lesions included pancreatic cancers (n = 134), neuroendocrine neoplasms (n = 15), metastatic tumors (n = 2), and a solid pseudopapillary neoplasm (n = 1). The diagnostic accuracy of EUS-FNB (combining histology and cytology) was 98.7%. However, the histopathological diagnosis was only confirmed for 64.3% of small lesions (<10 mm), relative to 97.2% for larger lesions. Multivariate analysis also revealed that lesion size of <10 mm predicted a less accurate histopathological diagnosis (odds ratio: 6.97, 95% confidence interval: 1.02–47.67; p = 0.041). Further analyses revealed a failed histological diagnosis in 4 patients with lesions of <5 mm in size and accurate diagnoses in 9 out of 10 patients with lesions of 5–10 mm in size. Conclusions: The diagnostic accuracy for small lesions (<10 mm), especially for lesions of <5 mm, based on histological examination alone, was significantly lower than that for others (>10 mm). Furthermore, multivariate analysis revealed that only lesion size was an independent predictor of histopathological diagnosis accuracy.

Original languageEnglish
Article number27
JournalDiagnostics
Volume11
Issue number1
DOIs
StatePublished - 2021/01

Keywords

  • EUS-FNB
  • Franseen needle
  • Histopathological assessment
  • Small pancreatic lesions

ASJC Scopus subject areas

  • Clinical Biochemistry

Fingerprint

Dive into the research topics of 'Diagnostic fine-needle biopsy of small solid pancreatic lesions using a franseen needle during endoscopic ultrasound examination'. Together they form a unique fingerprint.

Cite this