TY - JOUR
T1 - Accuracy of pedicle screw placement using patient-specific template guide system
AU - Fujita, Ryo
AU - Oda, Itaru
AU - Takeuchi, Hirohito
AU - Oshima, Shigeki
AU - Fujiya, Masanori
AU - Yahara, Yasuhito
AU - Kawaguchi, Yoshiharu
N1 - Publisher Copyright:
© 2021
PY - 2022/3
Y1 - 2022/3
N2 - Background: Despite repeated efforts for accurate cervical pedicle screw insertion, malpositioning of the inserted screw is commonly noted. To avoid neurovascular complications during cervical pedicle screw insertion, we have developed a new patient-specific screw guide system. This study aimed to evaluate the accuracy of cervical PS placement using the new patient-specific screw guide system. Methods: This study is a retrospective clinical evaluation of prospectively enrolled patients. Seventeen consecutively enrolled patients who underwent posterior cervical fusion using the guide system were included. Firstly, three-dimensional planning of pedicle screw placement was done using simulation software. A screw guide for each vertebra was constructed preoperatively. A total of 77 screws were inserted with the guides. Postoperative computed tomography was used to evaluate pedicle perforation, and screw deviations, between the planned and actual screw positions, were measured. Results: A total of 76 screws (98.7%) were completely inside the pedicle (C3-7), without neurovascular injuries. The mean screw deviations from the planned trajectory at the narrowest point of the pedicle and at the entry point in the axial and sagittal planes were 0.56 ± 0.43 mm and 0.43 ± 0.35 mm and 0.43 ± 0.30 mm and 0.63 ± 0.50 mm, respectively. There were no significant differences in any parameter at different spinal levels. Angular deviations in the sagittal and axial planes were 2.94 ± 2.04° and 2.53 ± 1.85°, respectively. Sagittal angular deviations tended to increase in the cranial vertebra (C3 and C4) compared to the middle cervical spine. Conclusions: We demonstrated that our patient-specific screw guide is vital for guiding precise screw insertion in the cervical pedicle. This technique may be an effective solution for achieving precise screw insertion and reducing the incidence of complications.
AB - Background: Despite repeated efforts for accurate cervical pedicle screw insertion, malpositioning of the inserted screw is commonly noted. To avoid neurovascular complications during cervical pedicle screw insertion, we have developed a new patient-specific screw guide system. This study aimed to evaluate the accuracy of cervical PS placement using the new patient-specific screw guide system. Methods: This study is a retrospective clinical evaluation of prospectively enrolled patients. Seventeen consecutively enrolled patients who underwent posterior cervical fusion using the guide system were included. Firstly, three-dimensional planning of pedicle screw placement was done using simulation software. A screw guide for each vertebra was constructed preoperatively. A total of 77 screws were inserted with the guides. Postoperative computed tomography was used to evaluate pedicle perforation, and screw deviations, between the planned and actual screw positions, were measured. Results: A total of 76 screws (98.7%) were completely inside the pedicle (C3-7), without neurovascular injuries. The mean screw deviations from the planned trajectory at the narrowest point of the pedicle and at the entry point in the axial and sagittal planes were 0.56 ± 0.43 mm and 0.43 ± 0.35 mm and 0.43 ± 0.30 mm and 0.63 ± 0.50 mm, respectively. There were no significant differences in any parameter at different spinal levels. Angular deviations in the sagittal and axial planes were 2.94 ± 2.04° and 2.53 ± 1.85°, respectively. Sagittal angular deviations tended to increase in the cranial vertebra (C3 and C4) compared to the middle cervical spine. Conclusions: We demonstrated that our patient-specific screw guide is vital for guiding precise screw insertion in the cervical pedicle. This technique may be an effective solution for achieving precise screw insertion and reducing the incidence of complications.
UR - http://www.scopus.com/inward/record.url?scp=85101514348&partnerID=8YFLogxK
U2 - 10.1016/j.jos.2021.01.007
DO - 10.1016/j.jos.2021.01.007
M3 - 学術論文
C2 - 33640220
AN - SCOPUS:85101514348
SN - 0949-2658
VL - 27
SP - 348
EP - 354
JO - Journal of Orthopaedic Science
JF - Journal of Orthopaedic Science
IS - 2
ER -